* Re: [9fans] Dell E4300?
2009-08-15 21:34 ` erik quanstrom
@ 2009-08-15 22:41 ` Benjamin Huntsman
0 siblings, 0 replies; 12+ messages in thread
From: Benjamin Huntsman @ 2009-08-15 22:41 UTC (permalink / raw)
To: Fans of the OS Plan 9 from Bell Labs
[-- Attachment #1: Type: text/plain, Size: 24918 bytes --]
>i'll add this southbridge to my cd. this will definately
>not hurt. could you send me pci output? if you use
>lspci from linux make sure to use -vn so the vid/did
>appear. the descriptive strings are fairly useless.
Sorry, I don't use Linux much. This machine currently runs OpenSolaris. Below is the output from 'prtconf -pv' which should be more-or-less similar to Linux's 'lspci -vn'. If you'd prefer the Linux output, I can go download a LiveCD really quick...
Thanks much for your time!!
-Ben
System Configuration: Sun Microsystems i86pc
Memory size: 4048 Megabytes
System Peripherals (PROM Nodes):
Node 0x000001
bios-boot-device: '82'
stdout: 00000000
name: 'i86pc'
Node 0x000002
existing: 00db2000.00000000.0bc58801.00000000
name: 'ramdisk'
Node 0x000003
bus-type: 'isa'
device_type: 'isa'
name: 'isa'
Node 0x000004
compatible: 'pciex_root_complex'
device_type: 'pciex'
reg: 00000000.00000000.00000000
#size-cells: 00000002
#address-cells: 00000003
name: 'pci'
Node 0x000005
reg: 00000000.00000000.00000000.00000000.00000000
compatible: 'pci8086,2a40.1028.24d.7' + 'pci8086,2a40.1028.24d' + 'pci1028,24d' + 'pci8086,2a40.7' + 'pci8086,2a40' + 'pciclass,060000' + 'pciclass,0600'
model: 'Host bridge'
power-consumption: 00000001.00000001
fast-back-to-back:
devsel-speed: 00000000
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '0'
class-code: 00060000
revision-id: 00000007
vendor-id: 00008086
device-id: 00002a40
name: 'pci1028,24d'
Node 0x000006
assigned-addresses: 83001010.00000000.f6c00000.00000000.00400000.c3001018.00000000.e0000000.00000000.10000000.81001020.00000000.0000ef98.00000000.00000008.a1001000.00000000.000003b0.00000000.0000000c.a1001000.00000000.000003c0.00000000.00000020.82001000.00000000.000a0000.00000000.00020000
reg: 00001000.00000000.00000000.00000000.00000000.03001010.00000000.00000000.00000000.00400000.43001018.00000000.00000000.00000000.10000000.01001020.00000000.00000000.00000000.00000008.a1001000.00000000.000003b0.00000000.0000000c.a1001000.00000000.000003c0.00000000.00000020.82001000.00000000.000a0000.00000000.00020000
compatible: 'pci8086,2a42.1028.24d.7' + 'pci8086,2a42.1028.24d' + 'pci1028,24d' + 'pci8086,2a42.7' + 'pci8086,2a42' + 'pciclass,030000' + 'pciclass,0300'
model: 'VGA compatible controller'
power-consumption: 00000001.00000001
fast-back-to-back:
devsel-speed: 00000000
interrupts: 00000001
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
device_type: 'display'
unit-address: '2'
class-code: 00030000
revision-id: 00000007
vendor-id: 00008086
device-id: 00002a42
name: 'display'
Node 0x000007
assigned-addresses: 83001110.00000000.f6b00000.00000000.00100000
reg: 00001100.00000000.00000000.00000000.00000000.03001110.00000000.00000000.00000000.00100000
compatible: 'pci8086,2a43.1028.24d.7' + 'pci8086,2a43.1028.24d' + 'pci1028,24d' + 'pci8086,2a43.7' + 'pci8086,2a43' + 'pciclass,038000' + 'pciclass,0380'
model: 'Video controller'
power-consumption: 00000001.00000001
fast-back-to-back:
devsel-speed: 00000000
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '2,1'
class-code: 00038000
revision-id: 00000007
vendor-id: 00008086
device-id: 00002a43
name: 'pci1028,24d'
Node 0x000008
assigned-addresses: 8200c810.00000000.f6ae0000.00000000.00020000.8200c814.00000000.f6adb000.00000000.00001000.8100c818.00000000.0000efe0.00000000.00000020
reg: 0000c800.00000000.00000000.00000000.00000000.0200c810.00000000.00000000.00000000.00020000.0200c814.00000000.00000000.00000000.00001000.0100c818.00000000.00000000.00000000.00000020
compatible: 'pci8086,10f5.1028.24d.3' + 'pci8086,10f5.1028.24d' + 'pci1028,24d' + 'pci8086,10f5.3' + 'pci8086,10f5' + 'pciclass,020000' + 'pciclass,0200'
model: 'Ethernet controller'
power-consumption: 00000001.00000001
devsel-speed: 00000000
interrupts: 00000001
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '19'
class-code: 00020000
revision-id: 00000003
vendor-id: 00008086
device-id: 000010f5
name: 'pci1028,24d'
Node 0x000009
assigned-addresses: 8100d020.00000000.00006f60.00000000.00000020
reg: 0000d000.00000000.00000000.00000000.00000000.0100d020.00000000.00000000.00000000.00000020
compatible: 'pci8086,2937.1028.24d.3' + 'pci8086,2937.1028.24d' + 'pci1028,24d' + 'pci8086,2937.3' + 'pci8086,2937' + 'pciclass,0c0300' + 'pciclass,0c03'
model: 'Universal Serial Bus UHCI compliant'
power-consumption: 00000001.00000001
fast-back-to-back:
devsel-speed: 00000001
interrupts: 00000001
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1a'
class-code: 000c0300
revision-id: 00000003
vendor-id: 00008086
device-id: 00002937
name: 'pci1028,24d'
Node 0x00000a
assigned-addresses: 8100d120.00000000.00006f80.00000000.00000020
reg: 0000d100.00000000.00000000.00000000.00000000.0100d120.00000000.00000000.00000000.00000020
compatible: 'pci8086,2938.1028.24d.3' + 'pci8086,2938.1028.24d' + 'pci1028,24d' + 'pci8086,2938.3' + 'pci8086,2938' + 'pciclass,0c0300' + 'pciclass,0c03'
model: 'Universal Serial Bus UHCI compliant'
power-consumption: 00000001.00000001
fast-back-to-back:
devsel-speed: 00000001
interrupts: 00000002
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1a,1'
class-code: 000c0300
revision-id: 00000003
vendor-id: 00008086
device-id: 00002938
name: 'pci1028,24d'
Node 0x00000b
assigned-addresses: 8100d220.00000000.00006fa0.00000000.00000020
reg: 0000d200.00000000.00000000.00000000.00000000.0100d220.00000000.00000000.00000000.00000020
compatible: 'pci8086,2939.1028.24d.3' + 'pci8086,2939.1028.24d' + 'pci1028,24d' + 'pci8086,2939.3' + 'pci8086,2939' + 'pciclass,0c0300' + 'pciclass,0c03'
model: 'Universal Serial Bus UHCI compliant'
power-consumption: 00000001.00000001
fast-back-to-back:
devsel-speed: 00000001
interrupts: 00000003
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1a,2'
class-code: 000c0300
revision-id: 00000003
vendor-id: 00008086
device-id: 00002939
name: 'pci1028,24d'
Node 0x00000c
assigned-addresses: 8200d710.00000000.fed1c400.00000000.00000400
reg: 0000d700.00000000.00000000.00000000.00000000.0200d710.00000000.00000000.00000000.00000400
compatible: 'pci8086,293c.1028.24d.3' + 'pci8086,293c.1028.24d' + 'pci1028,24d' + 'pci8086,293c.3' + 'pci8086,293c' + 'pciclass,0c0320' + 'pciclass,0c03'
model: 'Universal Serial Bus EHCI compliant'
power-consumption: 00000001.00000001
fast-back-to-back:
devsel-speed: 00000001
interrupts: 00000003
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1a,7'
class-code: 000c0320
revision-id: 00000003
vendor-id: 00008086
device-id: 0000293c
name: 'pci1028,24d'
Node 0x00000d
assigned-addresses: 8300d810.00000000.f6adc000.00000000.00004000
reg: 0000d800.00000000.00000000.00000000.00000000.0300d810.00000000.00000000.00000000.00004000
compatible: 'pciex8086,293e.1028.24d.3' + 'pciex8086,293e.1028.24d' + 'pciex8086,293e.3' + 'pciex8086,293e' + 'pciexclass,040300' + 'pciexclass,0403' + 'pci8086,293e.1028.24d.3' + 'pci8086,293e.1028.24d' + 'pci1028,24d' + 'pci8086,293e.3' + 'pci8086,293e' + 'pciclass,040300' + 'pciclass,0403'
model: 'Mixed Mode device'
power-consumption: 00000001.00000001
devsel-speed: 00000000
interrupts: 00000001
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1b'
class-code: 00040300
revision-id: 00000003
vendor-id: 00008086
device-id: 0000293e
name: 'pci1028,24d'
Node 0x00000e
reg: 0000e000.00000000.00000000.00000000.00000000
compatible: 'pciex8086,2940.3' + 'pciex8086,2940' + 'pciexclass,060400' + 'pciexclass,0604' + 'pci8086,2940.3' + 'pci8086,2940' + 'pciclass,060400' + 'pciclass,0604'
model: 'PCI-PCI bridge'
bus-range: 0000000b.0000000b
#size-cells: 00000002
#address-cells: 00000003
device_type: 'pciex'
power-consumption: 00000001.00000001
devsel-speed: 00000000
interrupts: 00000001
unit-address: '1c'
class-code: 00060400
revision-id: 00000003
vendor-id: 00008086
device-id: 00002940
pci-hotplug-type: 00000001
name: 'pci8086,2940'
Node 0x00000f
reg: 0000e100.00000000.00000000.00000000.00000000
compatible: 'pciex8086,2942.3' + 'pciex8086,2942' + 'pciexclass,060400' + 'pciexclass,0604' + 'pci8086,2942.3' + 'pci8086,2942' + 'pciclass,060400' + 'pciclass,0604'
model: 'PCI-PCI bridge'
ranges: 82000000.00000000.f6900000.82000000.00000000.f6900000.00000000.00100000
bus-range: 0000000c.0000000c
#size-cells: 00000002
#address-cells: 00000003
device_type: 'pciex'
power-consumption: 00000001.00000001
slot-names: 00000001.65696370.00000031
physical-slot#: 00000001
devsel-speed: 00000000
interrupts: 00000002
unit-address: '1c,1'
class-code: 00060400
revision-id: 00000003
vendor-id: 00008086
device-id: 00002942
pci-hotplug-type: 00000001
name: 'pci8086,2942'
Node 0x00001c
assigned-addresses: 830c0010.00000000.f69fe000.00000000.00002000
reg: 000c0000.00000000.00000000.00000000.00000000.030c0010.00000000.00000000.00000000.00002000
compatible: 'pciex8086,4235.8086.1121.0' + 'pciex8086,4235.8086.1121' + 'pciex8086,4235.0' + 'pciex8086,4235' + 'pciexclass,028000' + 'pciexclass,0280' + 'pci8086,4235.8086.1121.0' + 'pci8086,4235.8086.1121' + 'pci8086,1121' + 'pci8086,4235.0' + 'pci8086,4235' + 'pciclass,028000' + 'pciclass,0280'
model: 'Network controller'
power-consumption: 00000001.00000001
devsel-speed: 00000000
interrupts: 00000001
subsystem-vendor-id: 00008086
subsystem-id: 00001121
unit-address: '0'
class-code: 00028000
revision-id: 00000000
vendor-id: 00008086
device-id: 00004235
name: 'pci8086,1121'
Node 0x000010
reg: 0000e300.00000000.00000000.00000000.00000000
compatible: 'pciex8086,2946.3' + 'pciex8086,2946' + 'pciexclass,060400' + 'pciexclass,0604' + 'pci8086,2946.3' + 'pci8086,2946' + 'pciclass,060400' + 'pciclass,0604'
model: 'PCI-PCI bridge'
ranges: 81000000.00000000.0000d000.81000000.00000000.0000d000.00000000.00001000.82000000.00000000.f6600000.82000000.00000000.f6600000.00000000.00300000.c2000000.00000000.f0000000.c2000000.00000000.f0000000.00000000.00200000
bus-range: 0000000d.0000000e
#size-cells: 00000002
#address-cells: 00000003
device_type: 'pciex'
power-consumption: 00000001.00000001
slot-names: 00000001.65696370.00000033
physical-slot#: 00000003
devsel-speed: 00000000
interrupts: 00000004
unit-address: '1c,3'
class-code: 00060400
revision-id: 00000003
vendor-id: 00008086
device-id: 00002946
pci-hotplug-type: 00000001
name: 'pci8086,2946'
Node 0x000011
assigned-addresses: 8100e820.00000000.00006f00.00000000.00000020
reg: 0000e800.00000000.00000000.00000000.00000000.0100e820.00000000.00000000.00000000.00000020
compatible: 'pci8086,2934.1028.24d.3' + 'pci8086,2934.1028.24d' + 'pci1028,24d' + 'pci8086,2934.3' + 'pci8086,2934' + 'pciclass,0c0300' + 'pciclass,0c03'
model: 'Universal Serial Bus UHCI compliant'
power-consumption: 00000001.00000001
fast-back-to-back:
devsel-speed: 00000001
interrupts: 00000001
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1d'
class-code: 000c0300
revision-id: 00000003
vendor-id: 00008086
device-id: 00002934
name: 'pci1028,24d'
Node 0x000012
assigned-addresses: 8100e920.00000000.00006f20.00000000.00000020
reg: 0000e900.00000000.00000000.00000000.00000000.0100e920.00000000.00000000.00000000.00000020
compatible: 'pci8086,2935.1028.24d.3' + 'pci8086,2935.1028.24d' + 'pci1028,24d' + 'pci8086,2935.3' + 'pci8086,2935' + 'pciclass,0c0300' + 'pciclass,0c03'
model: 'Universal Serial Bus UHCI compliant'
power-consumption: 00000001.00000001
fast-back-to-back:
devsel-speed: 00000001
interrupts: 00000002
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1d,1'
class-code: 000c0300
revision-id: 00000003
vendor-id: 00008086
device-id: 00002935
name: 'pci1028,24d'
Node 0x000013
assigned-addresses: 8100ea20.00000000.00006f40.00000000.00000020
reg: 0000ea00.00000000.00000000.00000000.00000000.0100ea20.00000000.00000000.00000000.00000020
compatible: 'pci8086,2936.1028.24d.3' + 'pci8086,2936.1028.24d' + 'pci1028,24d' + 'pci8086,2936.3' + 'pci8086,2936' + 'pciclass,0c0300' + 'pciclass,0c03'
model: 'Universal Serial Bus UHCI compliant'
power-consumption: 00000001.00000001
fast-back-to-back:
devsel-speed: 00000001
interrupts: 00000003
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1d,2'
class-code: 000c0300
revision-id: 00000003
vendor-id: 00008086
device-id: 00002936
name: 'pci1028,24d'
Node 0x000014
assigned-addresses: 8200ef10.00000000.fed1c000.00000000.00000400
reg: 0000ef00.00000000.00000000.00000000.00000000.0200ef10.00000000.00000000.00000000.00000400
compatible: 'pci8086,293a.1028.24d.3' + 'pci8086,293a.1028.24d' + 'pci1028,24d' + 'pci8086,293a.3' + 'pci8086,293a' + 'pciclass,0c0320' + 'pciclass,0c03'
model: 'Universal Serial Bus EHCI compliant'
power-consumption: 00000001.00000001
fast-back-to-back:
devsel-speed: 00000001
interrupts: 00000001
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1d,7'
class-code: 000c0320
revision-id: 00000003
vendor-id: 00008086
device-id: 0000293a
name: 'pci1028,24d'
Node 0x000015
reg: 0000f000.00000000.00000000.00000000.00000000
compatible: 'pci8086,2448.93' + 'pci8086,2448' + 'pciclass,060401' + 'pciclass,0604'
model: 'Subtractive Decode PCI-PCI bridge'
ranges: 82000000.00000000.f6500000.82000000.00000000.f6500000.00000000.00100000
bus-range: 00000002.00000002
#size-cells: 00000002
#address-cells: 00000003
device_type: 'pci'
power-consumption: 00000001.00000001
devsel-speed: 00000000
unit-address: '1e'
class-code: 00060401
revision-id: 00000093
vendor-id: 00008086
device-id: 00002448
name: 'pci8086,2448'
Node 0x000019
assigned-addresses: 82020810.00000000.f65ff800.00000000.00000800
reg: 00020800.00000000.00000000.00000000.00000000.02020810.00000000.00000000.00000000.00000800
compatible: 'pci1180,832.1028.24d.5' + 'pci1180,832.1028.24d' + 'pci1028,24d' + 'pci1180,832.5' + 'pci1180,832' + 'pciclass,0c0010' + 'pciclass,0c00'
model: 'FireWire (IEEE 1394) OpenHCI compliant'
power-consumption: 00000001.00000001
devsel-speed: 00000001
interrupts: 00000001
max-latency: 00000004
min-grant: 00000002
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1'
class-code: 000c0010
revision-id: 00000005
vendor-id: 00001180
device-id: 00000832
name: 'pci1028,24d'
Node 0x00001a
assigned-addresses: 82020910.00000000.f65ff600.00000000.00000100
reg: 00020900.00000000.00000000.00000000.00000000.02020910.00000000.00000000.00000000.00000100
compatible: 'pci1180,822.1028.24d.22' + 'pci1180,822.1028.24d' + 'pci1028,24d' + 'pci1180,822.22' + 'pci1180,822' + 'pciclass,080501' + 'pciclass,0805'
model: 'Unknown class of pci/pnpbios device'
power-consumption: 00000001.00000001
devsel-speed: 00000001
interrupts: 00000002
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1,1'
class-code: 00080501
revision-id: 00000022
vendor-id: 00001180
device-id: 00000822
name: 'pci1028,24d'
Node 0x00001b
assigned-addresses: 82020a10.00000000.f65ff700.00000000.00000100
reg: 00020a00.00000000.00000000.00000000.00000000.02020a10.00000000.00000000.00000000.00000100
compatible: 'pci1180,843.1028.24d.12' + 'pci1180,843.1028.24d' + 'pci1028,24d' + 'pci1180,843.12' + 'pci1180,843' + 'pciclass,088000' + 'pciclass,0880'
model: 'System peripheral'
power-consumption: 00000001.00000001
devsel-speed: 00000001
interrupts: 00000002
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1,2'
class-code: 00088000
revision-id: 00000012
vendor-id: 00001180
device-id: 00000843
name: 'pci1028,24d'
Node 0x000016
reg: 0000f800.00000000.00000000.00000000.00000000
compatible: 'pci8086,2917.1028.24d.3' + 'pci8086,2917.1028.24d' + 'pci1028,24d' + 'pci8086,2917.3' + 'pci8086,2917' + 'pciclass,060100' + 'pciclass,0601'
model: 'ISA bridge'
power-consumption: 00000001.00000001
devsel-speed: 00000001
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1f'
class-code: 00060100
revision-id: 00000003
vendor-id: 00008086
device-id: 00002917
name: 'pci1028,24d'
Node 0x000017
assigned-addresses: 8100fa10.00000000.00006e70.00000000.00000008.8100fa14.00000000.00006e78.00000000.00000004.8100fa18.00000000.00006e80.00000000.00000008.8100fa1c.00000000.00006e88.00000000.00000004.8100fa20.00000000.00006ea0.00000000.00000020.8200fa24.00000000.fed1c800.00000000.00000800
reg: 0000fa00.00000000.00000000.00000000.00000000.0100fa10.00000000.00000000.00000000.00000008.0100fa14.00000000.00000000.00000000.00000004.0100fa18.00000000.00000000.00000000.00000008.0100fa1c.00000000.00000000.00000000.00000004.0100fa20.00000000.00000000.00000000.00000020.0200fa24.00000000.00000000.00000000.00000800
compatible: 'pci8086,2929.1028.24d.3' + 'pci8086,2929.1028.24d' + 'pci1028,24d' + 'pci8086,2929.3' + 'pci8086,2929' + 'pciclass,010601' + 'pciclass,0106'
model: 'SATA AHCI 1.0 Interface'
power-consumption: 00000001.00000001
66mhz-capable:
fast-back-to-back:
devsel-speed: 00000001
interrupts: 00000004
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1f,2'
class-code: 00010601
revision-id: 00000003
vendor-id: 00008086
device-id: 00002929
name: 'pci1028,24d'
Node 0x000018
assigned-addresses: 8300fb10.00000000.f6adaf00.00000000.00000100.8100fb20.00000000.00001100.00000000.00000020
reg: 0000fb00.00000000.00000000.00000000.00000000.0300fb10.00000000.00000000.00000000.00000100.0100fb20.00000000.00000000.00000000.00000020
compatible: 'pci8086,2930.1028.24d.3' + 'pci8086,2930.1028.24d' + 'pci1028,24d' + 'pci8086,2930.3' + 'pci8086,2930' + 'pciclass,0c0500' + 'pciclass,0c05'
model: 'SMBus (System Management Bus)'
power-consumption: 00000001.00000001
fast-back-to-back:
devsel-speed: 00000001
interrupts: 00000002
max-latency: 00000000
min-grant: 00000000
subsystem-vendor-id: 00001028
subsystem-id: 0000024d
unit-address: '1f,3'
class-code: 000c0500
revision-id: 00000003
vendor-id: 00008086
device-id: 00002930
name: 'pci1028,24d'
[-- Attachment #2: winmail.dat --]
[-- Type: application/ms-tnef, Size: 7564 bytes --]
^ permalink raw reply [flat|nested] 12+ messages in thread