From mboxrd@z Thu Jan 1 00:00:00 1970 From: andrey mirtchovski To: 9fans@cse.psu.edu Subject: Re: [9fans] now for something completely devfs :) In-Reply-To: <01eb95d1b74c640de263ed1bfb9e5e71@plan9.escet.urjc.es> Message-ID: MIME-Version: 1.0 Content-Type: TEXT/PLAIN; charset=US-ASCII Date: Wed, 9 Jul 2003 11:19:46 -0600 Topicbox-Message-UUID: f023bb02-eacb-11e9-9e20-41e7f4b1d025 My fossil is working, but I still want to know if /dev/sdC0/fossil (for example) changes while I'm dd-ing it to /dev/sdD0/fossil, will devfs take care of that discrepancy? The other question -- is there a way to know whether one or more of the mirrored disks have crashed and take measures? Watch the HDD light on the front panel? (A RAID controller we have here actually says that the only way to know if a disk has crashed is to reboot the machine -- then the controller BIOS will detect it.) andrey On Wed, 9 Jul 2003, Fco.J.Ballesteros wrote: > I did setup the mirror before formatting venti/fossil partitions. > > Otherwise, you'd need to copy one disk to another while the partitions > are idle. > > Let's say you have /dev/fs/mirror out of /dev/sdC0/part and /dev/sdC1/part > > If you add /dev/sdD0/part you could dd from either /dev/fs/mirror or > from /dev/sdC[01]/part to /dev/sdD0/part. You should also add the device > to devfs. > > I can help somehow, let me know. >