>> you need to be able to convey more information to pid 1 >> than a few signals can. >such as ? >what more information than the runlevel (0 or 6, maybe 1 to go >into single user) does SysV init need to start the system shutdown ? The time of the shutdown. The "shutdown" command isn't necessarily instantaneous, it can register a shutdown for a given time. You could deal with that by creating another process, which is equivalent to running a daemon outside pid 1 (and that's exactly what s6-linux-init-1.0.0.0 does), but if you want to handle it all in pid 1, you need time management in it and that can't be done via signals only. >the Void Linux team just made a shell script out of it that just brings >down the runit services and runsvdir itself. Yeah, that's not difficult. What is difficult is implementing the legacy features of other inits. -- Laurent